홈페이지> 블로그> Role of the pulse valve on the bag filter and the working principles

Role of the pulse valve on the bag filter and the working principles

March 16, 2021

The bag filter has the characteristics of high purification efficiency, large processing air volume, stable performance, long service life and wide application range. The equipment is widely used in metallurgy, foundry, chemical, building materials, grain, machinery, light industry, rubber and other industrial and mining enterprises for ventilation and dust removal, and has a good effect on improving the environment to prevent air pollution.
Working principle The dust-containing gas enters the bag filter from the air inlet pipe of the bag filter. After the uniform air action in the large space, the filter bag is evenly inserted. The material is trapped by the filter bag and deposited on the outer wall of the filter bag. The filtered clean gas After the venturi tube enters the upper tank, it is discharged from the exhaust pipe. The bag filter is equipped with an electromagnetic pulse valve, and the pulse valve is periodically opened, so that the compressed air is sprayed from the perforations of the blowing pipe to the corresponding venturi tubes, and the excess dust on the filter bag is cleared, so that the bag is kept ventilated smoothly and continuously. The material that was cleared was sent out by the auger in the lower part of the bag. Scope of application: In addition to the features of high purification efficiency, large processing volume, stable performance and long service life, the dmc pulse bag filter has the characteristics of high technical performance and wide application range. The equipment is widely used in power plant boilers, industrial boilers, steel mills, metallurgy, foundry, chemical, building materials, grain, machinery, light industry, rubber and other industrial and mining enterprises for ventilation and dust removal, to improve the environment, pulse valves, refers to electromagnetic or pneumatic The control of the pilot valve can open and close the diaphragm valve that generates the pulse at the high pressure air source. Electromagnetic pulse valve refers to a diaphragm valve that combines a solenoid valve, a pilot valve and a pulse valve, and is directly controlled by an electric signal.
According to the angle of the valve inlet and outlet and the form of the air inlet can be divided into three types:
a) Right-angle electromagnetic pulse valve: a diaphragm valve whose inlet and outlet are at right angles and directly controlled by electrical signals;
b) Straight-through electromagnetic pulse valve: a diaphragm valve whose inlet and outlet are 180 degrees and directly controlled by electric signals;
c) Submerged electromagnetic pulse valve: The diaphragm valve whose valve body inlet is submerged in the air bag and directly controlled by the electric signal.

문의하기

Author:

Mr. Jacky Guo

Phone/WhatsApp:

8613722852356

인기 상품
You may also like
Related Categories

이 업체에게 이메일로 보내기

제목:
이메일:
메시지:

Your message must be betwwen 20-8000 characters

문의하기

Author:

Mr. Jacky Guo

Phone/WhatsApp:

8613722852356

인기 상품
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

송신